Route electrical assessment
Record panel and service evidence, planned loads, proposed equipment data, circuits and disconnects without opening electrical equipment.
Site dependency map
Coordinate electrical assessment, line and circuit routing, condensate, defrost water, snow, sound, access and approvals.
Decision file
Record panel and service evidence, planned loads, proposed equipment data, circuits and disconnects without opening electrical equipment.
Map line-set, duct, wiring and condensate paths plus penetrations, fire or weather barriers and restoration.
Record setbacks or authority questions, airflow, service clearances, roof drainage, property boundaries and nearby windows or outdoor areas.
Ask where water goes in winter, how ice and erosion are considered and what maintenance remains.
Document roof shedding, drifting, vegetation and service access without prescribing stands or clearances.
Compare published data and proposed placement; actual perception and compliance depend on site conditions and current rules.
List safely documented service information, proposed outdoor and indoor equipment, auxiliary heat, disconnects and other planned loads. Require qualified load assessment and permit routing rather than inferring capacity from panel spaces or breaker labels.
Compare airflow clearance, snow accumulation, roof or grade drainage, prevailing weather, sound-sensitive windows, walkways, neighbour context, line-set distance and service access. Reject a location that works only in fair weather or blocks maintenance.
Draw refrigerant, electrical and condensate routes through the building with sleeves, air or water sealing, fire or acoustic interfaces and finish repair. Define who verifies gravity drainage or pump requirements and winter behaviour.
Show outdoor unit clearances, snow and drainage context, weather exposure, nearby windows and paths, service access, line-set and condensate routes, wall penetrations, indoor equipment and electrical supply. Connect proposed equipment and backup heat to the qualified load assessment, permit route and responsible trades. Identify finish repair, fire or acoustic interfaces and winter drainage review. Photograph concealed routes and final mounting. This drawing coordinates installation facts without declaring panel capacity, acceptable sound, weather resilience or drainage performance from a catalogue clearance alone. Review the drawing on site with the responsible HVAC, electrical and finish scopes before drilling or mounting. Record any route change, why it occurred and which affected detail was reapproved.
Primary references
Links checked in the approved research packet on August 26, 2026. Applicability still depends on the property and proposed scope.